Please use this identifier to cite or link to this item: http://dspace.utpl.edu.ec/handle/123456789/30806
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorCastillo Calvas, Tuesman Danieles_ES
dc.contributor.authorPalacios Mora, David Efrénes_ES
dc.date.accessioned2022-06-15T11:56:31Z-
dc.date.available2022-06-15T11:56:31Z-
dc.date.issued2022es_ES
dc.identifier.citationPalacios Mora, D. E. Castillo Calvas, T. D. (2022) Propuesta de calificación y certificación energética de la segunda y tercera planta alta del edificio principal, perteneciente a la Empresa Eléctrica Regional del Sur S.A., ubicado en la ciudad de Loja [Tesis de Posgrado, Universidad Técnica Particular de Loja]. Repositorio Institucional. https://dspace.utpl.edu.ec/handle/123456789/30806es_ES
dc.identifier.otherCobarc: 1354307es_ES
dc.identifier.urihttps://bibliotecautpl.utpl.edu.ec/cgi-bin/abnetclwo?ACC=DOSEARCH&xsqf99=130126.TITN.es_ES
dc.descriptionResumen: El uso de combustibles fósiles es causa del calentamiento global y de los efectos nocivos del cambio climático. Las pérdidas son enormes y los perjudicados son los seres vivos que habitamos en el planeta. Como parte de la solución para contrarrestar estos problemas se realizan análisis para la optimización del consumo energético en las edificaciones. Esto se puede corroborar gracias a la existencia de procedimientos y normas homologadas cuya aplicación dan como resultado el conocimiento de los niveles de calificación y certificación energética de la edificación en análisis. En el presente trabajo de titulación se realiza la propuesta de calificación y certificación energética en la segunda y tercera planta alta del edificio principal de la Empresa Eléctrica regional del Sur S.A. con la ayuda de herramientas informáticas homologadas como lo son CERMA y CE3X una vez que se obtuvo la calificación energética de la edificación en análisis se simularon medidas de mejora que aportaron con la reducción de emisiones de CO2 y el consumo de energía primaria no renovable, para finalmente obtener una nueva calificación con mejores resultados.es_ES
dc.description.abstractAbstract:The use of fossil fuels is the cause of global warming and the harmful effects of climate change. The losses are enormous and those affected are the living beings that inhabit the planet. As part of the solution to counteract these problems, analyzes are carried out to optimize energy consumption in buildings. This can be supported thanks to the existence of approved procedures and standards whose application results in knowledge of the energy qualification and certification levels of the building under analysis. In the present titling work, the proposal for qualification and energy certification is carried out on the second and third upper floors of the main building of the Empresa Eléctrica regional del Sur S.A. With the help of approved computer tools such as CERMA and CE3X, once the energy rating of the building under analysis was obtained, improvement measures were simulated that contributed to the reduction of CO2 emissions and the consumption of non-renewable primary energy, to finally get a new rating with better results.es_ES
dc.language.isospaes_ES
dc.subjectEcuador.es_ES
dc.subjectTesis digital.es_ES
dc.titlePropuesta de calificación y certificación energética de la segunda y tercera planta alta del edificio principal, perteneciente a la Empresa Eléctrica Regional del Sur S.A., ubicado en la ciudad de Lojaes_ES
dc.typemasterThesises_ES
Appears in Collections:Maestría en Gestión de Sistemas Energéticos en Edificaciones



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.