dc.identifier.citation | Tituana Tituana, K. B. Guillén Mena Vanessa Fernanda (2022) Percepción de confort térmico mediante la caracterización de la envolvente de edificaciones residenciales en la ciudad de Loja [Tesis de Posgrado, Universidad Técnica Particular de Loja]. Repositorio Institucional. https://dspace.utpl.edu.ec/handle/123456789/31207 | es_ES |
dc.identifier.other | Cobarc: 1355400 | es_ES |
dc.identifier.uri | https://bibliotecautpl.utpl.edu.ec/cgi-bin/abnetclwo?ACC=DOSEARCH&xsqf99=130683.TITN. | es_ES |
dc.description | Resumen: La implementación de la norma NEC-HS-EE es fundamental para la regulación de las edificaciones en eficiencia energética y confort térmico. El requisito principal es la transmitancia térmica de los elementos de envolvente, por ello, el presente estudio valida los valores máximos establecidos para la ciudad de Loja, y determina si estos son suficientes para garantizar que la percepción de confort térmico en las edificaciones residenciales sea aceptable. La investigación se basa en la información de la encuesta de edificaciones ENED, la aplicación de encuestas de sensación térmica y caracterización de envolvente, y el cálculo de transmitancia térmica mediante el método de cálculo teórico ISO 9646. Los resultados muestran que los paquetes constructivos de las tipologías predominantes T1 y T2 cumplen la normativa y brindan una sensación satisfactoria de confort a los ocupantes, a excepción de la pared de ladrillo de espesor 7cm, que es una práctica común. El mejor comportamiento térmico en las tipologías se presenta en la planta alta tanto en el día como en la noche, mientras menor confort se registra en la planta baja durante la noche. | es_ES |
dc.description.abstract | Abstract: The implementation of the NEC-HS-EE standard is essential for the regulation of buildings in terms of energy efficiency and thermal comfort. The main requirement is the thermal transmittance of the envelope elements, therefore, the present study validates the maximum values established for the city of Loja, and determines if these are necessary to guarantee that the perception of thermal comfort in residential buildings is acceptable. The research is based on the information from the ENED building survey, the application of thermal sensation surveys and envelope characterization, and the calculation of thermal transmittance using the ISO 9646 theoretical calculation method. The results show that the construction packages of the Predominant typologies T1 and T2 comply with the regulations and provide a satisfactory sensation of comfort to the occupants, with the exception of the 7cm thick brick wall, which is a common practice. The best thermal behavior in the typologies occurs on the upper floor both during the day and at night, while the least comfort is recorded on the ground floor at night. | es_ES |
dc.language.iso | spa | es_ES |
dc.subject | Ecuador. | es_ES |
dc.subject | Tesis digital. | es_ES |
dc.title | Percepción de confort térmico mediante la caracterización de la envolvente de edificaciones residenciales en la ciudad de Loja | es_ES |
dc.type | masterThesis | es_ES |
Aparece en las colecciones: | Maestría en Técnicas Constructivas para Edificaciones Sostenibles |
Ficheros en este ítem:
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.