Please use this identifier to cite or link to this item: http://dspace.utpl.edu.ec/handle/123456789/39157
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorBalcázar Arciniega, Cristian Andrées_ES
dc.contributor.authorApolo Márquez, Karina Alexandraes_ES
dc.date.accessioned2023-09-08T22:20:22Z-
dc.date.available2023-09-08T22:20:22Z-
dc.date.issued2023es_ES
dc.identifier.citationApolo Márquez, K. A. Balcázar Arciniega, C. A. (2023) Evaluación del confort higrotérmico, calidad del aire interior y ventilación de una vivienda unifamiliar y propuesta de rehabilitación pasiva [Tesis de Posgrado, Universidad Técnica Particular de Loja]. Repositorio Institucional. https://dspace.utpl.edu.ec/handle/123456789/39157es_ES
dc.identifier.otherCobarc: 1362361es_ES
dc.identifier.urihttps://bibliotecautpl.utpl.edu.ec/cgi-bin/abnetclwo?ACC=DOSEARCH&xsqf99=136398.TITN.es_ES
dc.descriptionResumen: El confort higrotérmico y la calidad del aire de un edificio son dos de los indicadores de la calidad ambiental interior que determina el bienestar del ocupante. La presente investigación seleccionó una vivienda unifamiliar como caso de estudio para validar una metodología de evaluación de estos parámetros en edificaciones existentes que consistió en el análisis climático del lugar, campañas de mediciones in situ de la temperatura y humedad relativa determinando inconfort térmico cuando la temperatura al exterior era más extrema, estos resultados se compararon estadísticamente con los reportes del simulador EcoDesigner. También se usó un sensor para medir las concentraciones de CO2, TVOC y HCHO, sin encontrar valores alarmantes en días típicos de ocupación. Se aplicaron encuestas de satisfacción y sensación térmica de los ocupantes y se verificó el cumplimiento o no de los requerimientos mínimos de los paquetes constructivos de la envolvente que por su escaso cumplimiento se planteó mejorar los elementos opacos mediante el uso de XPS como aislante en paredes de planta alta y recubrimiento de panel de yeso cartón con cámara de aire bajando los valores de transmitancia térmica.es_ES
dc.description.abstractAbstract: Hygrothermal comfort and the air quality of a building are two of the indicators of the indoor environmental quality that determines the well-being of the occupant. The present investigation selected a single-family home as a case study to validate a methodology of evaluation of these parameters in existing buildings that consisted of the analysis climate of the place, in situ measurement campaigns of temperature and relative humidity determining thermal discomfort when the temperature outside was more extreme, these Results were statistically compared with the EcoDesigner simulator reports. A sensor was also used to measure the concentrations of CO2, TVOC and HCHO, without find alarming values ​​on typical busy days. Surveys were applied satisfaction and thermal sensation of the occupants and compliance or non-compliance with the minimum requirements of the constructive packages of the envelope that, due to their scarcity compliance it was proposed to improve the opaque elements by using XPS as an insulator on upper floor walls and cardboard gypsum panel covering with an air chamber going down thermal transmittance values.es_ES
dc.language.isospaes_ES
dc.subjectEcuador.es_ES
dc.subjectTesis digital.es_ES
dc.titleEvaluación del confort higrotérmico, calidad del aire interior y ventilación de una vivienda unifamiliar y propuesta de rehabilitación pasivaes_ES
dc.typemasterThesises_ES
Appears in Collections:Maestría en Técnicas Constructivas para Edificaciones Sostenibles



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.