Please use this identifier to cite or link to this item:
http://dspace.utpl.edu.ec/handle/123456789/7944
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Ayala Mendoza, Adriana del Carmen | - |
dc.contributor.author | Encalada Chamba, Danny Paúl | - |
dc.date.accessioned | 2013-10-16T22:37:42Z | - |
dc.date.available | 2013-10-16 | - |
dc.date.issued | 2013 | - |
dc.identifier.citation | Encalada Chamba, Danny Paúl. (2013). Evaluación del comportamiento sísmico y cumplimiento de las normativas CEC 2000 y NEC-11 del edificio laboratorios de la UTPL. (Trabajo de Titulación de Ingeniero Civil). UTPL. Loja. | es_ES |
dc.identifier.other | 1135612 | - |
dc.identifier.uri | http://dspace.utpl.edu.ec/handle/123456789/7944 | - |
dc.description | En el presente trabajo investigativo se realiza la Evaluación del comportamiento sísmico y cumplimiento de las normativas CEC 2000 y NEC-11 del edificio laboratorios de la UTPL. Para cumplir con el objeto de investigación se realizó un levantamiento geométrico y ensayos de laboratorio, tanto destructivos y no destructivos con la finalidad de obtener características físicas y mecánicas de los elementos estructurales. Posteriormente se modeló el edificio por los métodos de análisis modal, espectral, Pushover, Demanda- Capacidad y análisis de historia en el tiempo. Finalmente con los resultados de cada uno de los análisis se formuló conclusiones y se presentó un procedimiento de evacuación complementario frente a un sismo, en función de los resultados de evaluación | es_ES |
dc.description.abstract | The current investigation is attended to determine the EVALUATION OF EARTHQUAKE PERFORMANCE AND COMPLIANCE OF THE NORMS CEC 2000 AND NEC CEC-11 OF LABORATORIES BUILDING UTPL. It was performed a geometric lifting and some laboratory tests in order to achieve the investigation´s goals in such a way that both destructive and nondestructive tests were performed for obtaining physical an mechanical characteristics of the structural elements. Later the building was modeled by modal analysis methods, spectral, Pushover, demand-capacity analysis and time history. Finally presented, the results of each analysis and conclusions, also, a supplementary evacuation procedure front an earthquake, depending on the evaluation results. | - |
dc.language.iso | es | es_ES |
dc.rights | openAccess | es_ES |
dc.subject | Ingeniería estructural | es_ES |
dc.subject | Diseño sismo resistente | es_ES |
dc.subject | Edificio de laboratorios -Evaluación sísmica | es_ES |
dc.subject | Ingeniero civil - Tesis y disertaciones académicas | es_ES |
dc.title | Evaluación del comportamiento sísmico y cumplimiento de las normativas CEC 2000 y NEC-11 del edificio laboratorios de la UTPL | es_ES |
dc.type | bachelorThesis | es_ES |
Appears in Collections: | Ingeniero Civil |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
BORRADOR 15.10.2013 FINAL.pdf | 3.49 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.