dc.identifier.citation | Morales Arciniega, S. D. Sanmartín Gutierrez, V. A. (2018) Validación del método de ensayo al fuego para oro y plata de muestras minerales [Tesis de Grado, Universidad Técnica Particular de Loja]. Repositorio Institucional. https://dspace.utpl.edu.ec/handle/20.500.11962/23334 | es_ES |
dc.identifier.other | Cobarc: 1284908 | es_ES |
dc.identifier.uri | https://bibliotecautpl.utpl.edu.ec/cgi-bin/abnetclwo?ACC=DOSEARCH&xsqf99=119866.TITN. | es_ES |
dc.description | Resumen: Este trabajo muestra los resultados de la validación del Ensayo al Fuego para oro y plata de muestras minerales en el cual se evaluaron los parámetros estadísticos: límite de detección, límite de cuantificación, exactitud, precisión e incertidumbre, usando sustancias de referencia certificadas para determinar si el método propuesto es apto para la cuantificación de estos metales. El método planteado para la determinación de estos metales es basado en el Ensayo al Fuego clásico por lo que su medición final se emplea la balanza analítica Ohaous que tiene una resolución d=0.00001. El método para la determinación de oro es apto para su cuantificación obteniendo una veracidad en la cual 80%<R<120%, coeficiente de variación de repetibilidad y reproducibilidad de 5.97% y una incertidumbre expandida de 12.49%. El método usado en el laboratorio no es apto para la determinación de plata incumpliendo con los parámetros estadísticos, teniendo una veracidad en la cual la recuperación no se encuentra dentro del 80% y 120% y coeficiente de variación de repetibilidad y reproducibilidad de 7.52% que es mayor al coeficiente de variación de Horwitz. | es_ES |
dc.description.abstract | Abstract: This work shows the results of the validation of the fire assay for gold and silver of mineral samples in which it shown by statistical calculations such as: linearity, limit of detection, limit of quantification, accuracy, precision and uncertainty, using certified reference substances to determine if the proposed method for the determination of these metals is adequate. The method proposed for the determination of these metals is based on the classic fire assay, so the analytical balance Ohaus is used for its final measurement which has a resolution of d=0.00001. The method for the determination of gold is suitable for its quantification, obtaining a veracity in which 80%<R<120%, coefficient of variation of repeatability and reproducibility of 5.97% and an expanded uncertainty of 12.49%. The method used in the laboratory is not suitable for the determination of silver since it does not comply with the statistical parameters, having a veracity in which the recovery is not within 80% and 120%, and a coefficient of variation of repeatability and reproducibility of 7.52% that is greater than the Horwitz variation coefficient. | es_ES |
dc.language.iso | spa | es_ES |
dc.subject | Ecuador. | es_ES |
dc.subject | Tesis digital. | es_ES |
dc.title | Validación del método de ensayo al fuego para oro y plata de muestras minerales | es_ES |
dc.type | bachelorThesis | es_ES |
Appears in Collections: | Ingeniero Químico |
Files in This Item:
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.