Please use this identifier to cite or link to this item: http://dspace.utpl.edu.ec/handle/20.500.11962/23676
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorCarrión Coronel, Eduardo Fernandoes_ES
dc.contributor.authorChamba Cabrera, Luis Migueles_ES
dc.date.accessioned2019-01-28T16:54:44Z-
dc.date.available2019-01-28T16:54:44Z-
dc.date.issued2019es_ES
dc.identifier.citationChamba Cabrera, L. M. Carrión Coronel, E. F. (2019) Estudio experimental de captaciones de fondo con medios porosos [Tesis de Grado, Universidad Técnica Particular de Loja]. Repositorio Institucional. https://dspace.utpl.edu.ec/handle/20.500.11962/23676es_ES
dc.identifier.otherCobarc: 1286669es_ES
dc.identifier.urihttps://bibliotecautpl.utpl.edu.ec/cgi-bin/abnetclwo?ACC=DOSEARCH&xsqf99=120722.TITN.es_ES
dc.descriptionResumen:Las captaciones de fondo son las de mayor uso en regiones montañosas. Los problemas de corrosión, deformación de las rejillas y el ingreso excesivo de sedimentos provocan que el sistema de potabilización sea lento y costoso y sugieren un nuevo sistema de captación de fondo, en la cual se reemplaza la rejilla por un medio poroso. La presente investigación se basó en estudiar experimentalmente el funcionamiento hidráulico de este nuevo sistema de captación de fondo, para lo cual, se diseña y construye un prototipo experimental; se evalúa el material óptimo para el medio poroso, y se realizan las pruebas de campo. Para cada prueba se determinó el caudal desviado y el perfil longitudinal de la superficie del agua. El aforo del caudal desviado se realizó para diferentes concretos porosos diseñados con grava de 1/2 y 3/4 de pulgada, así como pendientes longitudinales del canal que fueron 5%, 10%, 15%, y 20% en todas las pruebas.es_ES
dc.description.abstractAbstract:Bottom intake are the most commonly used in mountainous regions. The problems of corrosion, deformation of the racks, excessive entry of sediments cause that water treatment system because slow and expensive, which suggest a new bottom intake system, where the bottom racks are replaced by a porous medium. The present investigation is based on the experimental study of the hydraulic functioning of this new system of bottom intake, for what, an experimental prototype was designed and built; the optimum material for the porous medium is evaluated, and field tests carried out. For each test the deviated flow and the longitudinal profile of the water surface were determined. The capacity of the deviated flow was made for different porous concrete designed with gravel of 1/2 "and 3/4" of inch, as well as for different longitudinal slopes of the channel of 5%, 10%, 15%, and 20%.es_ES
dc.language.isospaes_ES
dc.subjectEcuador.es_ES
dc.subjectTesis digital.es_ES
dc.titleEstudio experimental de captaciones de fondo con medios porososes_ES
dc.typebachelorThesises_ES
Appears in Collections:Ingeniero Civil



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.