Please use this identifier to cite or link to this item: http://dspace.utpl.edu.ec/handle/20.500.11962/24955
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorCarrión Coronel, Eduardo Fernandoes_ES
dc.contributor.authorVivanco González, Daniel Alejandroes_ES
dc.date.accessioned2019-10-30T23:25:44Z-
dc.date.available2019-10-30T23:25:44Z-
dc.date.issued2019es_ES
dc.identifier.citationVivanco González, D. A. Carrión Coronel, E. F. (2019) Optimización de una captación convencional de agua superficial con la implementación de una rejilla de efecto Coanda [Tesis de N/D, Universidad Técnica Particular de Loja]. Repositorio Institucional. https://dspace.utpl.edu.ec/handle/20.500.11962/24955es_ES
dc.identifier.otherCobarc: 1306684es_ES
dc.identifier.urihttps://bibliotecautpl.utpl.edu.ec/cgi-bin/abnetclwo?ACC=DOSEARCH&xsqf99=122570.TITN.es_ES
dc.descriptionResumen:Las captaciones superficiales convencionales con rejillas de fondo presentan problemas de obstrucción de paso de agua debido al arrastre y acumulación de sedimentos en temporada de lluvias y acumulación de material orgánico en temporada de estiaje. En el presente proyecto de fin de titulación se plantea como objetivo optimizar una captación convencional de agua superficial con la implementación de una rejilla de efecto Coanda, el trabajo consiste en evaluar una capación mediante una inspección del estado físico de las estructuras, aforo de caudales, toma de muestras y cálculo de volúmenes de sedimentos acumulados para diseñar una rejilla no convencional que mejore las condiciones de trabajo hidráulico y lograr una mayor retención de sedimentos. Los resultados de la optimización son favorables ya que se obtuvo una retención de sedimentos del 94.7 % en comparación a las muestras tomadas con la rejilla convencional. El ingreso de caudal actual comparado con los aforos realizados con la nueva rejilla disminuyo en 37.63% en temporada de estiaje y 63.76% en temporada de lluvias sin embargo se mejoró la calidad de agua que ingresa a la obra de toma. Palabras Clave:.es_ES
dc.description.abstractAbstract:Conventional surface water abstractions with bottom intake bars present problems of flow clogging due to dragging and accumulation of sediments during the rainy season and accumulation of organic material during the dry season. The main purpose of this project is to optimize a conventional surface water abstraction with the implementation of the Coanda effect on the screen bars. The work was carried out by evaluating the water abstraction through a survey of the physical state of the structures, flow rate measurement, sampling and calculation of accumulated sediment volumes to design an unconventional screen that improves hydraulic working conditions and achieves greater sediment retention. The results are favorable since a sediment retention of 94.7% was obtained in comparison to the samples taken with the conventional bars. The current flow income compared to the measure flows made with the new screen decreased by 37.63% in the dry season and 63.76% in the rainy season. However, water quality was improved at intake structures.es_ES
dc.language.isospaes_ES
dc.subjectEcuador.es_ES
dc.subjectTesis digital.es_ES
dc.titleOptimización de una captación convencional de agua superficial con la implementación de una rejilla de efecto Coandaes_ES
dc.typemasterThesises_ES
Appears in Collections:Ingeniero Civil



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.