dc.identifier.citationAguilar Quezada, C. H. Soto Luzuriaga, J. E. (2020) Correlación entre el ensayo EPOL y SPT para predecir la capacidad admisible de suelos arenosos y finos de consistencia rígida a muy dura [Tesis de Posgrado, Universidad Técnica Particular de Loja]. Repositorio Institucional. https://dspace.utpl.edu.ec/handle/20.500.11962/26719es_ES
dc.identifier.otherCobarc: 1345279es_ES
dc.identifier.urihttps://bibliotecautpl.utpl.edu.ec/cgi-bin/abnetclwo?ACC=DOSEARCH&xsqf99=124240.TITN.es_ES
dc.descriptionResumen: El diseño de la cimentacióndeviviendas de hasta dos plantas, según lo estipulado en la normativa Ecuatoriana NEC 15 se basa actualmente, en analizar visualmente la calidad razonable del suelo, sin embargo, para el diseño de la cimentación de obras de ingeniería es necesario disponer de la capacidad admisible del suelo. En virtud de lo mencionado se desarrollaron formulaciones para predecir la capacidad admisible del suelo, relacionando el ensayo SPT y el ensayo EPOL de uso local. Para cumplir con este objetivo se analizaron treinta y seis estudios de suelos desarrollados por la empresa GICA en la zona urbana de la ciudad de Loja, convalidados posteriormente con ensayos de campo y formulaciones alternativas. Los resultados obtenidos mostraron un factor de correlación de 1.96 para suelosno cohesivos y 1.15 para suelos cohesivos, con los cuales se modificaron las formulaciones de Meyerhof (1974). Para la validación de los cálculos analíticos se utilizaron las formulaciones de Parry (1997) aplicado a suelos cohesivos, Mohr Coulomb y cálculos en base a la energía cinética, resultado la formulación de Meyerhof (1974), la más conservadora.es_ES
dc.description.abstractAbstract: Thedesign of the foundations of houses with up to two floors, as stipulated in the Ecuadorian regulation NEC 15, is currently based on visually analyzing the reasonable quality of the soil, however, for the design of the foundations of engineering works it is necessary to have of the allowable capacity of the soil. By virtue of the aforementioned, formulations were developed to predict the admissible capacity of the soil, relating the SPT test and the EPOL test for local use. To meet this objective, thirty-six soil studies developed by the GICA company in the urban area of the city of Loja were analyzed, subsequently validated with field trials and alternative formulations. The results obtained showed a correlation factor of 1.96 for non-cohesive soils and 1.15 for cohesive soils, with which the formulations of Meyerhof (1974) were modified. For the validation of the analytical calculations, the formulations of Parry (1997) applied to cohesive soils, Mohr-Coulomb and calculations based on kinetic energy were used, resulting in the formulation of Meyerhof (1974), the most conservative.es_ES
dc.language.isospaes_ES
dc.subjectEcuador.es_ES
dc.subjectTesis digital.es_ES
dc.titleCorrelación entre el ensayo EPOL y SPT para predecir la capacidad admisible de suelos arenosos y finos de consistencia rígida a muy duraes_ES
dc.typemasterThesises_ES
Appears in Collections:Maestría en Geotecnia Aplicada



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.