Please use this identifier to cite or link to this item: http://dspace.utpl.edu.ec/handle/20.500.11962/26726
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorGonzaga Vallejo, Sonia Lorenaes_ES
dc.contributor.authorBalcázar Quizhpe, Josué Israel.es_ES
dc.date.accessioned2020-10-14T12:36:03Z-
dc.date.available2020-10-14T12:36:03Z-
dc.date.issued2020es_ES
dc.identifier.citationBalcázar Quizhpe, J. I. Gonzaga Vallejo, S. L. (2020) Evaluación y catastro de la red de alcantarillado sanitario del campus de la Universidad Técnica Particular de Loja [Tesis de N/D, Universidad Técnica Particular de Loja]. Repositorio Institucional. https://dspace.utpl.edu.ec/handle/20.500.11962/26726es_ES
dc.identifier.otherCobarc: 1345305es_ES
dc.identifier.urihttps://bibliotecautpl.utpl.edu.ec/cgi-bin/abnetclwo?ACC=DOSEARCH&xsqf99=124266.TITN.es_ES
dc.descriptionResumen: El catastro de alcantarillado sanitario es el requisito necesario para realizar una evaluación, control y mantenimiento óptimo de un sistema de saneamiento. Debido al crecimiento de infraestructura en el campus UTPL y la falta de información de sus componentes, se planteó como objetivo realizar el levantamientodel catastro de alcantarillado sanitario y su evaluación de funcionamiento. Para satisfacer estas necesidades se ejecutó la recopilación de información en fichas técnicas donde figuran datos relevantesde cada componente.Para su ubicación y posterior mantenimiento,los pozos fueron referenciados tanto geográficamente como a dos puntos fijos; y se calculó el caudal de descarga para cada edificio del campus tomando en consideración el número de baterías sanitarias existentes. Con esta información, finalmente se realizóla evaluaciónde la capacidadhidráulica mediante el uso del software SewerGems, aplicando la norma INEN (1992). Como resultado se encontró queel caudal que trasiega en el campus es de 103 L/s, constituido pordos redes principales de alcantarillado sanitario detubería PVC corrugada de 200 mm, cuyas descargas se unen al sistema de alcantarillado pluvial, constituyéndose en un sistema mixto.es_ES
dc.description.abstractAbstract: The sanitary sewerage cadastre is the necessary requirement for an optimal evaluation, control and maintenance of a sanitation system. Due to the growth of infrastructure in the UTPL campus and the lack of information of its components, it was proposed as an objective to carry out the survey of the sanitary sewage cadastre and its operation evaluation. In order to satisfy these needs, information was collected in technical files where relevant data of each component is included. For their location and subsequent maintenance, the wells were referenced both geographically and to two fixed points; and the discharge flow was calculated for each building on the campus taking into consideration the number of existing sanitary batteries. With this information, finally the evaluation of the hydraulic capacity was made by means of the use of the SewerGems software, applying the INEN (1992) standard. As a result, it was found that the flow rate in the campus is 103 L/s, made up of two main sanitary sewage networks of corrugated PVC pipe of 200 mm, whose discharges are joined to the rainwater sewage system, constituting a mixed system.es_ES
dc.language.isospaes_ES
dc.subjectEcuador.es_ES
dc.subjectTesis digital.es_ES
dc.titleEvaluación y catastro de la red de alcantarillado sanitario del campus de la Universidad Técnica Particular de Lojaes_ES
dc.typemasterThesises_ES
Appears in Collections:Ingeniero Civil



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.