Please use this identifier to cite or link to this item: http://dspace.utpl.edu.ec/handle/20.500.11962/26934
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorGarcía Berfon, Luis Vicente.es_ES
dc.contributor.authorMelgar Gálvez, Guissella Katherine.es_ES
dc.date.accessioned2020-11-10T17:03:35Z-
dc.date.available2020-11-10T17:03:35Z-
dc.date.issued2020es_ES
dc.identifier.citationMelgar Gálvez, G. K. García Berfon, L. V. (2020) Estudio de la capacidad de remoción de sulfuro de hidrógeno en corrientes de biogás empleando arcillas ecuatorianas modificadas con Fe y Zn [Tesis de N/D, Universidad Técnica Particular de Loja]. Repositorio Institucional. https://dspace.utpl.edu.ec/handle/20.500.11962/26934es_ES
dc.identifier.otherCobarc: 1345568es_ES
dc.identifier.urihttps://bibliotecautpl.utpl.edu.ec/cgi-bin/abnetclwo?ACC=DOSEARCH&xsqf99=124575.TITN.es_ES
dc.descriptionResumen: En este trabajo se estudió la capacidad de remoción de H2S, de una arcilla ecuatoriana, modificada con Na, Fe y Zn y adaptada morfológicamente a la forma de extrudados. La capacidad de remoción de H2S fue evaluada, empleando un filtro de lecho fijo que contenía los extrudados, acoplado a una corriente de biogás, con 2.2 % de H2S, y un flujo de 1mL/s, a una presión manométrica de 2 psig, temperatura ambiente de 30°C. La corriente de biogás provenía de un biorreactor anaeróbico de tratamiento de vinaza. La concentración de H2S a la entrada y la salida del filtro fue determinada, mediante ampollas GASTEC 4H y 4HH, empleando una bomba de aspiración GASTEC GV-100-S-TR. Los mejores resultados se obtuvieron con el sólido 15%Na12%Fe15%Zn, el cual mantuvo sus características de sorción por 660 minutos antes de saturarse, removiendo 2.31 mili moles de H2S/gramo de sorbente.es_ES
dc.description.abstractAbstract: In this work, the H2S removal capacity of an Ecuadorian clay, modified with Na, Fe and Zn and morphologically adapted to formextrudates, was studied. The H2S removal capacity was evaluated, using a fixed bed filter that contained the extrudates, coupled to a biogas stream, with 2.2 % H2S, and a flow of 1mL / s, at a gauge pressure of 2 psig, and roomtemperature of 30 ° C. The biogas stream came from an anaerobic vinasse treatment bioreactor. The H2S concentration at the inlet and outlet of the filter was determined by means of GASTEC 4H and 4HH ampoules, using a GASTEC GV-100-S-TR aspiration pump. The best results were obtained with the solid 15%Na12%Fe15%Zn, which maintained its sorption characteristics for 660 minutes before reached the saturating and removing2.31 milli moles of H2S / gram of sorbent.es_ES
dc.language.isospaes_ES
dc.subjectEcuador.es_ES
dc.subjectTesis digital.es_ES
dc.titleEstudio de la capacidad de remoción de sulfuro de hidrógeno en corrientes de biogás empleando arcillas ecuatorianas modificadas con Fe y Znes_ES
dc.typemasterThesises_ES
Appears in Collections:Ingeniero Químico



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.