Please use this identifier to cite or link to this item: http://dspace.utpl.edu.ec/jspui/handle/20.500.11962/21759
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorAguilar Ramírez, Silvio David-
dc.contributor.authorGómez Castro, Alvaro Damián-
dc.date.accessioned2018-02-02T19:54:36Z-
dc.date.available2018-02-02T19:54:36Z-
dc.date.issued2018-
dc.identifier.citationGómez Castro, Alvaro Damián. 82018). Determinación de plomo y cadmio por espectroscopia de absorción atómica con horno de grafito, para la evaluación de la calidad del agua en afluentes cercanos al volcán Cotopaxi. (Trabajo de Titulación de Ingeniero en Gestión Ambiental ). UTPL, Quitoes_ES
dc.identifier.other1275475-
dc.identifier.urihttp://dspace.utpl.edu.ec/handle/20.500.11962/21759-
dc.descriptionEn el presente trabajo se estudió la calidad del agua de dos importantes efluentes del volcán Cotopaxi, específicamente el río Pita y el río Cutuchi. El estudio se enmarcó objetivamente en la determinación de plomo y cadmio por espectroscopia de absorción atómica con horno de grafito; y cobre y zinc por espectroscopia de absorción atómica de llama, las dos técnicas fueron desarrolladas en el Laboratorio LASA ubicado en la ciudad de Quito. En cada uno de los ríos se establecieron tres puntos de muestreo. La toma de muestras se realizó en dos épocas distintas del presente año (febrero y junio). Se tomaron además, datos de campo como pH, temperatura y conductividad, para aportar aún más a la línea base. El agua del rio Pita y rio Cutuchi no cumplen con la normativa TULSMA Tabla 2 en los parámetros Pb, Zn y Cu respectivamente. No se encontraron diferencias significativas entre las dos épocas del año de acuerdo al análisis ANOVA (p>0,05), sin embargo en verano (junio) tanto el plomo como el cadmio tienden a concentrarse ligeramente en ambos ríos. El zinc y cobre se mantienen estables en las dos épocases_ES
dc.description.abstractIn the present work, the water quality of two important effluents of the Cotopaxi volcano, the Pita and Cutuchi rivers, was studied. The study was objectively framed in the determination of lead and cadmium by atomic absorption spectroscopy with graphite furnace; as well as copper and zinc by atomic absorption spectroscopy with flame, the two techniques were developed in the LASA Laboratory in Quito-Ecuador. In each of the rivers, three sampling points were established. Samples were taken at two different times in 2017. In addition, field data such as pH, temperature and conductivity were taken to further contribute to the baseline. The water from the Pita and Cutuchi rivers do not comply with the TULSMA regulations Table 2 in the parameters Pb, Zn and Cu respectively. No significant differences were found between the two seasons of the year according to the ANOVA analysis (p> 0.05), however in June both the lead and the cadmium tend to concentrate slightly in both rivers. Zinc and copper remain stable at both times.es_ES
dc.language.isospaes_ES
dc.subjectAgua-- -Análisis químicoes_ES
dc.subjectVolcán Cotopaxi – Afluentes – Estudioes_ES
dc.subjectRíos- Calidad del agua - Cotopaxi (Ecuador)es_ES
dc.subjectIngeniero en gestión ambiental – Tesis y disertaciones académicases_ES
dc.titleDeterminación de plomo y cadmio por espectroscopia de absorción atómica con horno de grafito, para la evaluación de la calidad del agua en afluentes cercanos al volcán Cotopaxi.es_ES
dc.typebachelorThesises_ES
Appears in Collections:Ingeniero en Gestión Ambiental

Files in This Item:
File Description SizeFormat 
Gomez Castro Alvaro.pdf2.55 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.