dc.identifier.citationGonzaga Aguilar, Pablo Andrés. (2016). Validación de métodos analíticos para la Determinación de Metales Pesados ( Cu, Fe, Zn, Mn y Pb), mediante Absorción Atómica en las matrices de Aguas Residuales, Naturales y de Consumo Humano en los laboratorios UTPL. (Trabajo de Titulación de Ingeniero Químico ). UTPL, Loja.es_ES
dc.identifier.other1174876-
dc.identifier.urihttp://dspace.utpl.edu.ec/handle/123456789/14695-
dc.descriptionLa validación de métodos analíticos para la determinación de metales pesados (Cu, Fe, Mn, Zn y Pb) por espectrofotometría de absorción atómica en las matrices de agua residual, natural y de consumo humano, comienza con la revisión de métodos normalizados, para metales pesados en aguas. La validación se la realiza para el cumplimiento de requisitos de la norma ISO/IEC: 17025, Standard Methods, Guía Eurachem. La metodología empleada fue el método de llama aire-acetileno, con el Espectrofotómetro de Absorción Atómica de marca Perkin Elmer 400. Para garantizar el proceso de validación, se analizaron los siguientes requisitos exigidos: rango de trabajo, linealidad del método, límite de detección, límite de cuantificación, exactitud, incertidumbre y precisión. Se determinó mediante análisis estadístico que se cumplió con los diferentes criterios para cada analito metálico, entre estos tenemos: veracidad (80% < %R < 120%), linealidad presentando un coeficiente de correlación (r2) mayor a 0.995, y finalmente una incertidumbre (≤ 30 % (K=2)) en todos los niveles de concentración. .es_ES
dc.description.abstractThe Validation of analytical methods for the determination of heavy metals (Cu, Fe, Mn, Zn and Pb) by atomic absorption spectrophotometer in matrices residual, natural and human consumption begins with a review of standardized methods for heavy metals presents in water. The validation is done to perform the requirements of ISO / IEC 17025, Standard Methods, Eurachem Guide. The methodology used was the method of air-acetylene flame, with Atomic Absorption Spectrophotometer Perkin Elmer 400. To ensure the validation process, the following requirements were analyzed: working range, linearity of the method, detection limit, quantification limit, accuracy, precision and uncertainty. It is determined by statistical analysis meet the various criteria for each metal analyst, among these are: accuracy (80% <% R <120%), linearity showing a correlation coefficient (r2) It is greater than 0.995 and finally an uncertainty (≤ 30% (K = 2)) at all concentration levelses_ES
dc.languagespaes_ES
dc.subjectEspectrofotometría de absorción atómicaes_ES
dc.subjectMetales pesados – Contaminaciónes_ES
dc.subjectAguas residuales - Análisises_ES
dc.subjectAgua – Consumoes_ES
dc.subjectIngeniero químico – Tesis y disertaciones académicas.es_ES
dc.titleValidación de métodos analíticos para la Determinación de Metales Pesados ( Cu, Fe, Zn, Mn y Pb), mediante Absorción Atómica en las matrices de Aguas Residuales, Naturales y de Consumo Humano en los laboratorios UTPLes_ES