Please use this identifier to cite or link to this item: http://dspace.utpl.edu.ec/handle/123456789/14711
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorZárate Torres, Belizario Amador-
dc.contributor.authorRey Granda, Mireya Estefanía-
dc.date.accessioned2016-04-27T22:40:07Z-
dc.date.available2016-04-27-
dc.date.issued2016-
dc.identifier.citationRey Granda, Mireya Estefanía. (2016). Determinación de factores para ajuste de volúmenes de tránsito en la vía Loja – Zamora E50. (Trabajo de Titulación de Ingeniero Civil). UTPL, Loja.es_ES
dc.identifier.other1174978-
dc.identifier.urihttp://dspace.utpl.edu.ec/handle/123456789/14711-
dc.descriptionA través del presente trabajo de fin de titulación, se pretende determinar los factores de ajuste de volúmenes de tránsito en la vía Loja – Zamora E50, con el objetivo de que sean aplicables a otras vías de similares características y a otros periodos de tiempo. Para cada mes del año 2015 se han establecido los factores de ajuste mensual, así como también los factores de ajuste diario de la semana seleccionada y detallada en el capítulo correspondiente a análisis de resultados. Las mediciones de los volúmenes de tráfico para el presente estudio, se los ha realizado con un contador de tipo neumático denominado MetroCount 5600 el mismo que ha sido instalado en un tramo de la vía Loja-Zamora E50 en el kilómetro 5+300 provisto de dos sensores instalados en forma transversal a la vía. El tiempo destinado de aforo se lo ha realizado durante tres meses y de forma continua, para de esta manera obtener datos representativos y sobre todo reales de los volúmenes de transito de la vía Loja-Zamora.es_ES
dc.description.abstractThrough the present degree thesis, we try to determine the adjustment factors of traffic volume on the road Loja - Zamora E50, the purpose is to apply to other roads with similar characteristics and other time periods. For each month of 2015 establish monthly adjustment factors, as well as the daily adjustment factors, selected and detailed in the section on analysis of results Chapter. For the measurements of traffic volumes for this study, we use a pneumatic counter called MetroCount 5600 installed on a stretch of road Loja – Zamora E50 in 5+300 kilometers, equipped with sensors installed transversely to the road. The measurements were performed was three months continuously, to obtain representative data and especially actual of traffic volumes of road Loja - Zamora.es_ES
dc.languagespaes_ES
dc.subjectTránsito – Lojaes_ES
dc.subjectAforo vehiculares_ES
dc.subjectVolúmenes de tráfico – Control – Lojaes_ES
dc.subjectControl del tráficoes_ES
dc.subjectIngeniero civil -Tesis y disertaciones académicases_ES
dc.titleDeterminación de factores para ajuste de volúmenes de tránsito en la vía Loja – Zamora E50es_ES
dc.typebachelorThesises_ES
Appears in Collections:Ingeniero Civil

Files in This Item:
File Description SizeFormat 
Rey Granda, Mireya Estefania.pdf2.39 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.